• Newsroom
  • Contact
  • safe&easy
  • DE EN PL
Results out of Read more Products View all results

Share

Share this page

You can share this page with others by sending the URL of the selected page.

email LinkedIn
FPP-01 FPP-01 - AC Filter for PCB mounting en IM0005246

Series: FPP-01

Free Sample Request

AC Filter for PCB Mounting Cost Optimized

22 Variants


Description FPP-01

Description

  • Line filter in standard and medical version
  • 1 stage
  • standard attenuation

Characteristics

  • Cost-saving plastic housing
    Designed for standard applications
  • Protection against interference voltage from the mains
    Possible interferences generated in the equipment are strongly attenuated
  • For standard applications
  • Suitable for use in equipment according to IEC/UL 60950

Other versions on request

  • Version with wire connection
  • Medical version M80
Date Subcategory Language Title Download
21/02/2019
Flyers English Flyer Components and Solutions for Medical Equipment
24/11/2017
White Paper English White Paper Leakage currents
30/06/2016
EMC English PCB Library PCB-Filters
20/04/2016
PCS English FPP-45

Ratings IEC

Ratings IEC


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

0.6 - 6 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

Ratings UL


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

0.6 - 6 A @ Ta 40 °C / 125 VAC; 60 Hz

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.
Leakage Current

standard < 0.25 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)

Dielectric Strength

Dielectric Strength


Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.

Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-25 °C to 85 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

25/085/21 acc. to IEC 60068-1

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information

Insulation cover

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Terminals


Terminals according IEC Standard.

Detailed information about terminals can be looked up in the date sheet or in the general product information.
Terminal

For PCB mounting , tin-plated

Material: Housing

Thermoplastic, black, UL 94V-0

Line Filter

Filter Type


Filter classification according leakage current for easy reading:

Standard: < 0.5 mA
Medical: < 0.1 mA

Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8
Technical Details

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.
MTBF

> 200'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals

SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: FPP2

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 40004673
Approval marks cURus UL UL File Number: E72928


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Partners IEC_Certification_Body Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Partners UL_Certification_Body Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Partners UL_Certification_Body Designed according to UL 1283 Electromagnetic interference filters
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.
Partners IEC_Certification_Body Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1

Preview
 

Picture(s) Selection of product pictures to display a specific variant of the type

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 
Model Description
 

Model Description Abbreviated description of the CAD model

IGS
 

IGS Also mentioned as IGES ( Initial Graphics Exchange Specification). Common program indipendent interchange format for 3D CAD data.

Step
 

Step Also mentioned as STEP ( Standard for the Exchange of Product Model Data). Common program indipendent interchange format for 3D CAD data standardized according ISO standard.

Parasolid
 

Parasolid Parasolid modeling kernel is a 3D CAD systems. It is developed by a separate business unit within the Unigraphics Solutions (UGS), now Siemens PLM Software.

DXF
 

DXF (Drawing Interchange Format) is a specified by the Autodesk file format for CAD data exchange, and was developed for the 2D-CAD program AutoCAD. A DXF file describes a CAD model as plain text to the ASCII standard.

FPP-01
5500.2000 5500.2001 5500.2002 5500.2003 5500.2004 5500.2116 5500.2117 5500.2118 5500.2119 5500.2120
5500.XXXX
FPP-01
5500.2005 5500.2006 5500.2007 5500.2008 5500.2121 5500.2122 5500.2123 5500.2124
5500.XXXX
FPP-01
5500.2009 5500.2010 5500.2125 5500.2126
5500.XXXX

Dimension [mm]

Case 13P

Case 18P

Case 24P

1) Line
2) Load

Diagrams

S1 standard version

1) Line
2) Load
S2 medical version

1) Line
2) Load

Attenuation Loss

0.6 A

1 A

2 A

4 A

6 A

0.7 A

1 A

2 A

3 A

1 A

3 A

0.6 A

1 A

2 A

4 A

6 A

0.7 A

1 A

2 A

3 A

1 A

3 A


Short Table of Variants FPP-01 Open complete table FPP-01


Rated Current [A] Filter-Type L [mH] Order Number

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .

This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.

This approach offers to use generic alias link to the product details:

www.schurter.xx/art/ [Order Number]

where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:

- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle

Contact us for availability on other product variants, lead-times vary:
Contact-Form

Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links reffers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.

The
Distributor Stock Check
Stock Check Distributor

...
 
0.6 Standard Version 2 x 40 5500.2000  A  ...
1 Standard Version 2 x 10 5500.2001  A  ...
2 Standard Version 2 x 4 5500.2002  A  ...
4 Standard Version 2 x 1.5 5500.2003  A  ...
6 Standard Version 2 x 0.8 5500.2004 ...
0.7 Standard Version 2 x 40 5500.2005 ...
1 Standard Version 2 x 20 5500.2006 ...
2 Standard Version 2 x 6 5500.2007 ...
3 Standard Version 2 x 3 5500.2008  A  ...
1 Standard Version 2 x 30 5500.2009 ...
3 Standard Version 2 x 4 5500.2010 ...
0.6 Medical Version (M5) 2 x 40 5500.2116 ...
1 Medical Version (M5) 2 x 10 5500.2117 ...
2 Medical Version (M5) 2 x 4 5500.2118 ...
4 Medical Version (M5) 2 x 1.5 5500.2119 ...
6 Medical Version (M5) 2 x 0.8 5500.2120 ...
0.7 Medical Version (M5) 2 x 40 5500.2121 ...
1 Medical Version (M5) 2 x 20 5500.2122 ...
2 Medical Version (M5) 2 x 6 5500.2123 ...
3 Medical Version (M5) 2 x 3 5500.2124 ...
1 Medical Version (M5) 2 x 30 5500.2125 ...
3 Medical Version (M5) 2 x 4 5500.2126 ...

Most Popular.

Alternative: Standard version (0)

[Swipe to the left and right for more options]


se.schurter.com
en
en
prod //cdn.schurter.com