TA45-2PAU Circuit Breaker for Equipment thermal, 2 pole, Push button actuation, with auxiliary contact, with undervoltage

Series: TA45-2PAU

Free Sample Request

Circuit Breaker for Equipment thermal, 2 pole, Push button actuation, with auxiliary contact, with undervoltage

Description TA45-2PAU

Description

  • Thermal circuit breaker
  • 1 or 2 pole thermal overload protection
  • Positively trip-free release
  • High configurability
  • Snap-in or flange mounted
  • Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x 6 mm (lineside P1, P2)

Applications

  • Power tools
  • Industrial appliances
  • Power supplies
Date Subcategory Language Title Download
21/02/2019
White Paper English White Paper Selecting rated currents for CBE
07/03/2017
PCN English TA45 PCN
24/06/2016
PCN English TA45 Rocker and Push Button, 2-, 3-Pole

Rated Voltage AC

AC 240 V

Rated Voltage DC

60 V

Rated current range AC

0.05 - 20 A

Conditional short circuit capacity

IEC: Inc, PC1, AC 240 V: 1 kA 

Degree of Protection

from front side IP40 acc. to IEC 60529

Dielectric Strength

4 kV

Insulation Resistance

500 VDC > 100 MΩ

Lifetime

mechanical: 50'000 switching cycles

AC: 1 x Ir:
50'000 switching cycles

DC: 1 x Ir:
50'000 switching cycles

Overload

AC: min. 40 trips
@ 6 x Ir

DC: min. 50 trips
@ 4 x Ir

Allowable Operation Temp.

-10 °C to 55 °C

Vibration Resistance

± 0.75 mm @ 5 - 60 Hz
acc. to IEC 60068-2-6, test Fc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc

Shock Resistance

30 G / 18 ms
acc. to IEC 60068-2-27, test Ea

Possible Tripping Types

Thermal  Undervoltage release  Remote trip  Mechanical lock-out latch

Actuation Type

Pushbutton 

Weight

45 - 60 g

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals

SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: TA45

Approval Logo Certificates Certification Body Description
Approval marks VDE VDE VDE Certificate Number: 40019880
Approval marks cURus UL UL File Number: E71572
Approval marks ccc CCC CCC Certificate Number: 2013010307660082


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60934 Circuit-breakers for equipment (CBE)
Partners UL_Certification_Body Designed according to UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment
Partners CSA_Certification_Body Designed according to CSA C22.2 No. 235 Supplementary Protectors
Partners CCC_Certification_Body Designed according to GB 17701 Circuit-breaker for equipment


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

Preview
 

Picture(s) Selection of product pictures to display a specific variant of the type

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 
Model Description
 

Model Description Abbreviated description of the CAD model

IGS
 

IGS Also mentioned as IGES ( Initial Graphics Exchange Specification). Common program indipendent interchange format for 3D CAD data.

Step
 

Step Also mentioned as STEP ( Standard for the Exchange of Product Model Data). Common program indipendent interchange format for 3D CAD data standardized according ISO standard.

Parasolid
 

Parasolid Parasolid modeling kernel is a 3D CAD systems. It is developed by a separate business unit within the Unigraphics Solutions (UGS), now Siemens PLM Software.

DXF
 

DXF (Drawing Interchange Format) is a specified by the Autodesk file format for CAD data exchange, and was developed for the 2D-CAD program AutoCAD. A DXF file describes a CAD model as plain text to the ASCII standard.

Dimension [mm]

Snap-in type and quick connect terminal with auxiliary contact
Undervoltage release, remote trip release
A) Quick connect terminal, IEC 61210, A6.3-0.8 mm
B) Quick connect terminal, IEC 61210, A2.8-0.8 mm␉
Snap-in type and quick connect terminal with auxiliary contact
Mechanical lock-out latch
A) Quick connect terminal, IEC 61210, A6.3-0.8 mm


*) max. switching stroke
Flange type and quick connect terminal with auxiliary contact
Undervoltage release, remote trip release
A) Quick connect terminal, IEC 61210, A6.3-0.8 mm
B) Quick connect terminal, IEC 61210, A2.8-0.8 mm␉
Flange type and quick connect terminal with auxiliary contact
Mechanical lock-out latch
A) Quick connect terminal, IEC 61210, A6.3-0.8 mm


*) max. switching stroke

Cut-out and pin-out

Cut-out snap-in type

1) Assemble
2) edge must be sharp
Cut-out flange type / Installation from rear

Cut-out flange type/ Installation from rear with AZZ05 cover

Pin-out

*) Auxiliary contact

Diagrams

1pole thermal overload protection, Auxiliary contact

1pole thermal overload protection, Auxiliary contact, Shunt terminal

2pole thermal overload protection, Auxiliary contact

2pole thermal overload protection, Auxiliary contact, Shunt terminal

Undervoltage release

Undervoltage release with additional contact

Undervoltage release with 2 additional contacts

Remote trip release

Mechanical lock-out latch


Time-Current-Curves

Time in Seconds
Multiple of Rated Current In


Reference Temperature +23°
Time in Seconds
Multiple of Rated Current In


Reference Temperature +23°
Time in Seconds
Multiple of Rated Current In


Reference Temperature +23°

Effect of ambient temperature

Ambient Temperature [°C] Correction factor
-10 0.89
-5 0.91
0 0.92
+23 1.00
+30 1.03
+40 1.08
+55 1.16

Auxiliary contact (changeover)

Rated Voltage 28 VDC 60 VDC 240 VAC
Rated current max. 10 A resistive load max. 2 A resistive load max. 2 A cos φ 0.7

Undervoltage release

Max. operating voltage             1.1 Ue
Rated operating voltage Ue 5 V 12 V 24 V 48 V 120 V 240 V 400 V 1)
Current consumption (± 10%) 10.5 mA 16.5 mA 17.0 mA 3.2 mA 3.7 mA 3.1 mA 2.65 mA
Highest reset level             0.85 Ue
Lowest trip level             0.20 Ue
Trip delay             20 ms - 50 ms
Impulse withstand voltage (1.2 / 50 µs)             ≥4 kV
1) only for 3pole

Remote trip

Permissible impuls duration of the make contact (no) Between terminal C and P1 unlimited
Electrical load of the make contact (no) Current max. 12 mA / power max. 1.1 W  


TA45 - AK2 W F 120 A2 - AZM11
The characters are placeholders for the correspondingly keys of selections from the key tables.

TA45 - AK2 W F 120 A2 - AZM11 = Basic function
Basic function Configuration key
2-pole, push button, 1pole overload protection, auxiliary contact, flat connection, snap-in type, push button gasket IP40 AUL
2-pole, push button, 1pole overload protection, auxiliary contact, flat connection, snap-in type, push button gasket IP65 AUU
2-pole, push button, 1pole overload protection, auxiliary contact, flat connection, flange type, push button gasket IP40 ALL
2-pole, push button, 1pole overload protection, auxiliary contact, flat connection, flange type, push button gasket IP65 ALU
2-pole, push button, 1pole overload protection, auxiliary contact, screw connection, snap-in type, push button gasket IP40 AXL
2-pole, push button, 1pole overload protection, auxiliary contact, screw connection, snap-in type, push button gasket IP65 AXU
2-pole, push button, 1pole overload protection, auxiliary contact, screw connection, flange type, push button gasket IP40 APL
2-pole, push button, 1pole overload protection, auxiliary contact, screw connection, flange type, push button gasket IP65 APU
2-pole, push button, 1p overload protection, auxiliary contact and shunt terminal, flat connection, snap-in type, push button gasket IP40 AUM
2-pole, push button, 1p overload protection, auxiliary contact and shunt terminal, flat connection, snap-in type, push button gasket IP65 AUV
2-pole, push button, 1p overload protection, auxiliary contact and shunt terminal, flat connection, flange type, push button gasket IP40 ALM
2-pole, push button, 1p overload protection, auxiliary contact and shunt terminal, flat connection, flange type, push button gasket IP65 ALV
2-pole, push button, 1p overload protection, auxiliary contact and shunt terminal, screw connection, snap-in type, push button gasket IP40 AXM
2-pole, push button, 1p overload protection, auxiliary contact and shunt terminal, screw connection, snap-in type, push button gasket IP65 AXV
2-pole, push button, 1p overload protection, auxiliary contact and shunt terminal, screw connection, flange type, push button gasket IP40 APM
2-pole, push button, 1p overload protection, auxiliary contact and shunt terminal, screw connection, flange type, push button gasket IP65 APV
2-pole, push button, 2p overload protection, auxiliary contact, flat connection, snap-in type, push button gasket IP40 AUN
2-pole, push button, 2p overload protection, auxiliary contact, flat connection, snap-in type, push button gasket IP65 AUW
2-pole, push button, 2p overload protection, auxiliary contact, flat connection, flange type, push button gasket IP40 ALN
2-pole, push button, 2p overload protection, auxiliary contact, flat connection, flange type, push button gasket IP65 ALW
2-pole, push button, 2p overload protection, auxiliary contact, screw connection, snap-in type, push button gasket IP40 AXN
2-pole, push button, 2p overload protection, auxiliary contact, screw connection, snap-in type, push button gasket IP65 AXW
2-pole, push button, 2p overload protection, auxiliary contact, screw connection, flange type, push button gasket IP40 APN
2-pole, push button, 2p overload protection, auxiliary contact, screw connection, flange type, push button gasket IP65 APW
2-pole, push button, 2p overload protection, auxiliary contact and shunt terminal, flat connection, snap-in type, push button gasket IP40 AUP
2-pole, push button, 2p overload protection, auxiliary contact and shunt terminal, flat connection, snap-in type, push button gasket IP65 AUX
2-pole, push button, 2p overload protection, auxiliary contact and shunt terminal, flat connection, flange type, push button gasket IP40 ALP
2-pole, push button, 2p overload protection, auxiliary contact and shunt terminal, flat connection, flange type, push button gasket IP65 ALX
2-pole, push button, 2p overload protection, auxiliary contact and shunt terminal, screw connection, snap-in type, push button gasket IP40 AXP
2-pole, push button, 2pole overload protection, auxiliary contact, screw connection, snap-in type, push button gasket IP65 AXX
2-pole, push button, 2p overload protection, auxiliary contact and shunt terminal, screw connection, flange type, push button gasket IP40 APP
2-pole, push button, 2p overload protection, auxiliary contact and shunt terminal, screw connection, flange type, push button gasket IP65 APX


TA45 - AK2 W F 120 A2 - AZM11 = Actuator colour
Actuator colour Configuration key
Front Black: Green/Red T
Front Yellow: Green/Red U
Front Grey: Green/Red V


TA45 - AK2 W F 120 A2 - AZM11 = Legend
Legend Configuration key
embossed Configuration key Logo F
white printed Configuration key Logo H
black printed Configuration key Logo K
white printed Configuration key Logo L
black printed Configuration key Logo M
white printed Configuration key Logo P
black printed Configuration key Logo R
white printed Configuration key Logo S
black printed Configuration key Logo T


TA45 - AK2 W F 120 A2 - AZM11 = Rated current
Rated current Configuration key
0.05 A Z05
0.1 A J01
0.2 A J02
0.3 A J03
0.4 A J04
0.5 A J05
0.6 A J06
0.7 A J07
0.8 A J08
0.9 A J09
1.0 A J10
1.1 A J11
1.2 A J12
1.3 A J13
1.4 A J14
1.5 A J15
1.6 A J16
1.7 A J17
1.8 A J18
1.9 A J19
2.0 A J20
2.1 A J21
2.2 A J22
2.3 A J23
2.5 A J25
2.8 A J28
3.0 A 030
3.5 A 035
4.0 A 040
4.5 A 045
5.0 A 050
6.0 A 060
6.5 A 065
7.0 A 070
7.5 A 075
8.0 A 080
9.0 A 090
10.0 A 100
11.0 A 110
12.0 A 120
13.0 A 130
14.0 A 140
15.0 A 150
16.0 A 160
17.0 A 170
18.0 A 180
19.0 A 190
20.0 A 200
Other rated currents on request


TA45 - AK2 W F 120 A2 - AZM11 = Release / lock-out latch
Release / lock-out latch Configuration key
whithout release / lock-out latch C0
Undervoltage release, rated voltage 240 V AC U2
Undervoltage release, rated voltage 230 V AC U3
Undervoltage release, rated voltage 120 V AC U4
Undervoltage release, rated voltage 48 V AC / DC U6
Undervoltage release, rated voltage 24 V AC / DC U7
Undervoltage release, rated voltage 12 V AC / DC U8
Undervoltage release, rated voltage 5 V AC / DC U9
Undervoltage release with additional contact, rated voltage 240 V AC E2
Undervoltage release with additional contact, rated voltage 230 V AC E3
Undervoltage release with additional contact, rated voltage 120 V AC E4
Undervoltage release with additional contact, rated voltage 48 V AC / DC E6
Undervoltage release with additional contact, rated voltage 24 V AC / DC E7
Undervoltage release with additional contact, rated voltage 12 V AC / DC E8
Undervoltage release with additional contact, rated voltage 5 V AC / DC E9
Undervoltage release with 2 additional contacts, rated voltage 240 V AC Z2
Undervoltage release with 2 additional contacts, rated voltage 230 V AC Z3
Undervoltage release with 2 additional contacts, rated voltage 120 V AC Z4
Undervoltage release with 2 additional contacts, rated voltage 48 V AC / DC Z6
Undervoltage release with 2 additional contacts, rated voltage 24 V AC / DC Z7
Undervoltage release with 2 additional contacts, rated voltage 12 V AC / DC Z8
Undervoltage release with 2 additional contacts, rated voltage 5 V AC / DC Z9
Remote trip release, rated voltage 240 V AC A2
Remote trip release, rated voltage 230 V AC A3
Remote trip release, rated voltage 120 V AC A4
Remote trip release, rated voltage 48 V AC / DC A6
Remote trip release, rated voltage 24 V AC / DC A7
Remote trip release, rated voltage 12 V AC / DC A8
Mechanical lock-out latch S0


TA45 - AK2 W F 120 A2 - AZM11 = Accessories
Factory mounted accessories Configuration key
Without cover  
For subsequent fitting accessories see:
Accessories CBE


Accessories (1)

[Swipe to the left and right for more options]

TA45-ACC

Accessories to TA45


se.schurter.com
en
en
prod //cdn.schurter.com